智算中心 · 托管与互联 · GPU 算力服务AI data centers · Colocation · GPU cloud

为 AI 而建的
算力底座。
The compute foundation,
built for AI.

从整座液冷智算中心,到单卡 GPU 云服务器,Branpont 为您设计、建设、托管并运营训练与推理所需的基础设施。From an entire liquid-cooled AI data center to a single-GPU instance, Branpont designs, builds, hosts and runs the infrastructure behind your training and inference.

140 kW液冷单柜设计功率(最高)Max design power per liquid-cooled rack
≤1.25设计 PUEDesign PUE
3.2 Tb/s单节点 RDMA 带宽(8 × 400G)RDMA bandwidth per node (8 × 400G)
7×2424/7NOC 监控与现场支持NOC monitoring and on-site support

以上为示例设计指标,具体以项目合同与现场条件为准。Representative design targets; final figures depend on site and contract.

三种服务形态Three delivery models

自建、托管或按需使用,
由您决定。
Build it, colocate it,
or use it on demand.

三种形态共享同一套工程标准与同一支运维团队。您可以从任意一种开始,并随业务规模灵活组合。All three run on one engineering standard and one operations team. Start with any of them and combine them as you grow.

智算中心(AIDC)AI data centers (AIDC)

由我们为您规划、设计并建设面向 GPU 集群的智算中心,交付可上电、可运行的设施,并可长期代为运营。We plan, design and build an AI data center for your GPU clusters, hand it over powered and running, and can operate it for you long term.

适合Best for
政企、云厂商、大模型公司Public sector, enterprises, cloud providers, AI labs
交付Delivery
设计·建设·运营Design–build–operate
规模Scale
MW 级园区Megawatt-scale campuses
了解智算中心Explore AI data centers

托管与互联Colocation & interconnection

把您的服务器放进高密度、运营商中立的数据中心,配套网络互联与 7×24 现场支持。Place your own servers in high-density, carrier-neutral facilities, with interconnection and 24/7 on-site support.

适合Best for
已有服务器的团队Teams with their own hardware
交付Delivery
机柜 · 机笼 · 包间 · 模块Racks, cages, suites, halls
计费Billing
机柜·月或 kW·月Per rack or per kW, monthly
了解托管与互联Explore colocation

GPU 算力服务GPU cloud

无需自购硬件,按需使用 GPU 云服务器、GPU 裸金属服务器与专属训练集群。Use GPU instances, bare-metal GPU servers and dedicated training clusters without buying hardware.

适合Best for
按需使用算力的团队Teams that want compute on demand
交付Delivery
实例 · 裸金属 · 集群Instances, bare metal, clusters
计费Billing
按量 · 包年包月 · 预留On-demand, subscription, reserved
了解 GPU 算力服务Explore GPU cloud

智算中心(AIDC)AI data centers (AIDC)

规划、设计、建设、运营,
一体交付。
Plan, design, build, operate.
One team, start to finish.

智算中心是为 GPU 集群而设计的数据中心:更高的单柜功率、液冷散热与无损网络。我们按设计·建设·运营模式交付,每个阶段都有明确的交付物与验收标准。An AI data center is built around GPU clusters: denser racks, liquid cooling and lossless networking. We deliver it design–build–operate, with clear deliverables and acceptance criteria at every phase.

  1. 规划咨询Plan

    可研 · TCOFeasibility · TCO

    评估可获得的电力容量(MW)、能评与选址政策、网络时延与水资源,测算 TCO,制定分期上电方案。We assess available power (MW), energy-review and siting requirements, network latency and water, then build a TCO model and a phased power-on plan.

  2. 工程设计Design

    GB 50174 A 级 · Tier IIIGB 50174 Class A · Tier III

    统筹高密度供配电、液冷、楼板承重与组网,按 GB 50174 A 级与 Uptime Tier III 标准设计。High-density power, liquid cooling, floor loading and network topology, designed together to GB 50174 Class A and Uptime Tier III.

  3. EPC 交付Build (EPC)

    设计—采购—施工Engineer · procure · construct

    以 EPC 总承包模式统一负责设计、采购与施工;预制模块化缩短建设与上电周期,按里程碑验收。EPC delivery under one contract for design, procurement and construction. Prefabricated modules shorten time to power, with acceptance at each milestone.

  4. 调试验证Commission

    L1–L5

    L1–L5 分级调试,满载假负载测试与冗余切换演练,出具验收报告。Level 1–5 commissioning, full-load testing with load banks and failover drills, closed out with an acceptance report.

  5. 运营运维Operate

    7×24 NOC24/7 NOC

    7×24 NOC 与 DCIM 监控,持续优化能效;也可为政府、国企或投资方提供智算中心代运营。24/7 NOC and DCIM monitoring with ongoing efficiency tuning — or we run the entire facility for government, state-owned or investor owners.

工程能力Engineering capabilities

高密度设计High-density design

液冷机位单柜设计功率 40–140 kW,可部署 GB300 NVL72 等整机柜系统;风冷区与液冷区分区规划。Liquid-cooled positions designed for 40–140 kW per rack, ready for rack-scale systems such as GB300 NVL72, with separate air- and liquid-cooled zones.

40–140 kWNVL72风液混合Hybrid air–liquid

液冷系统集成Liquid cooling integration

以冷板式液冷(DLC)为主、浸没式液冷按需,覆盖 CDU、二次侧管网、Manifold 与漏液监测。Direct-to-chip (cold-plate) liquid cooling first, immersion cooling where it fits — CDUs, secondary loop, manifolds and leak detection.

冷板式Cold-plateCDU漏液监测Leak detection

供配电与储能Power and energy storage

2N UPS 或 HVDC 供电、柴发 N+1,可选储能(BESS),并为 800 VDC 架构预留升级路径。2N UPS or HVDC, N+1 generators and optional battery storage (BESS), with an upgrade path to 800 VDC.

2NHVDC800 VDC

预制模块化Prefabricated modular

电力模块、液冷模块与预制机房在工厂集成、现场拼装,缩短建设与上电周期。Power, cooling and data-hall modules are integrated in the factory and assembled on site, shortening time to power.

工厂预制Factory-built分期扩容Phased expansion

存量机房高密度改造High-density retrofits

楼体不动,通过风改液、加装 CDU 或背板空调(RDHx)提升单柜功率,可分区分批实施。Raise rack density in an existing building with air-to-liquid conversion, added CDUs or rear-door heat exchangers (RDHx), zone by zone.

风改液Air-to-liquidCDURDHx

绿色低碳Sustainability

通过绿电直连、绿证与 PPA 提高可再生能源占比;余热回收与算电协同进一步降低能耗与排放。Direct green-power supply, green certificates and PPAs raise the renewable share; heat reuse and grid-aware scheduling cut energy use and emissions further.

绿电直连Direct green power余热回收Heat reuse算电协同Grid-aware scheduling

功率、标准与周期为示例设计指标,具体以项目合同与现场条件为准。Power ratings, standards and timelines are representative design targets; final figures depend on site and contract.

托管与互联Colocation & interconnection

把服务器放进
为高密度而生的机房。
Your servers, in a facility
built for density.

从单个机柜到整个数据机房:零售型、批发型与定制化建设(BTS)托管,配套运营商中立的网络互联。From a single rack to an entire data hall: retail, wholesale and build-to-suit colocation, with carrier-neutral interconnection.

零售型机柜托管Retail colocation

以单机柜、机笼或包间为单位,含电力、制冷与安防,带宽按需选配。By the rack, cage or private suite, with power, cooling and security included; add bandwidth as you need it.

起租From
单机柜One rack
合同Term
通常 1–3 年Typically 1–3 years

高密度 AI-Ready 托管AI-ready high-density colocation

为 GPU 服务器与整机柜系统提供液冷机位与配套组网。Liquid-cooled positions for GPU servers and rack-scale systems, with the networking to match.

单柜Per rack
40–140 kW
散热Cooling
冷板式液冷Direct-to-chip

批发型托管Wholesale colocation

整租数据机房或模块,由您自主部署与运营,签订长期合约。Lease a whole data hall or module and run it your way, on a long-term contract.

起租From
1 MW
合同Term
长期合约Long-term

定制化建设(BTS)Build-to-suit (BTS)

按云厂商或大模型公司的规格专建园区或楼栋,也可只交付土建与供电(Powered Shell)。A campus or building built to your specification — or a powered shell you fit out yourself.

交付Delivery
交钥匙或 Powered ShellTurnkey or powered shell
规模Scale
按需定制To your spec

网络与互联Network & interconnection

一处接入,连通运营商、公有云与您的其他站点。One place to reach carriers, public clouds and your other sites.

运营商中立的接入让您自主选择上游线路;交叉连接、云专线与数据中心互联让训练数据在园区、公有云与站点之间高速流动。Carrier-neutral access lets you choose your upstream. Cross-connects, cloud on-ramps and DCI move training data quickly between campuses, public clouds and your sites.

  • BGP 多线:电信、联通、移动多线接入,支持固定带宽或 95 计费Multi-carrier BGP — China Telecom, China Unicom and China Mobile, billed at a fixed rate or 95th percentile
  • 运营商中立:多家运营商与 ISP 入驻,自主选择上游线路Carrier-neutral — multiple carriers and ISPs on site, so you choose the upstream
  • 交叉连接:在机房内以光纤直连运营商、云厂商与合作伙伴Cross-connects — direct fiber to carriers, clouds and partners inside the building
  • 云专线:不经公网,直连主流公有云,构建混合云与多云Cloud on-ramps — private links to major public clouds for hybrid and multi-cloud
  • 数据中心互联(DCI):园区之间、城域与跨区域的高速光传输Data center interconnect (DCI) — high-speed optical links between campuses, across metros and regions
  • DDoS 防护:BGP 引流清洗,按防护带宽分级提供DDoS mitigation — BGP diversion and scrubbing, tiered by protected bandwidth

单柜功率与起租规模为示例指标,具体以园区资源与合同为准。Rack densities and minimums are representative; final terms depend on the site and contract.

运维服务Managed services

从上架那天起,
7×24 在场。
On site around the clock,
from day one.

远程协助、专家现场支持与驻场代维覆盖设备的全生命周期;GPU、InfiniBand 与液冷节点由专业工程师处理。Remote hands, smart hands and resident engineers cover the whole hardware lifecycle, with specialists for GPU, InfiniBand and liquid-cooled nodes.

  • 按故障等级约定响应时限Response times agreed by severity
  • 工单、巡检与变更全程留痕Every ticket, inspection and change on record
  • 托管客户与智算中心业主均可选用Available to colocation customers and AIDC owners alike
部署上架Rack and stack设备到货On arrival
到货验收Receiving checks上架布线Racking & cabling加电测试Power-on test
集群验收与可靠性工程Cluster acceptance & reliability上线之前Before go-live
烤机Burn-inNCCL / HPL有效训练时长Goodput
远程协助Remote hands7×2424/7
重启Reboots线缆插拔Cable moves状态核对Status checks
专家现场支持Smart handsGPU · IB · 液冷GPU · IB · liquid cooling
故障诊断Troubleshooting部件更换Part swaps配置调优Tuning
驻场代维Resident engineering长期驻场Ongoing
巡检Inspections变更管理Change management备品备件Spares
机房搬迁与迁移Migration & relocation按项目Per project
迁移方案Planning设备搬迁Relocation业务割接Cutover

GPU 算力服务GPU cloud

从一张卡,
到千卡集群。
From a single GPU
to clusters of thousands.

GPU 算力服务(算力租赁)让您无需自购硬件,即可获得训练与推理所需的算力:小规模任务分钟级开通,大规模训练使用专属集群,资源与计费方式按需组合。GPU cloud gives you compute for training and inference without buying hardware. Small jobs start in minutes, large runs get dedicated clusters, and you mix resources and billing to fit.

01 — 训练Training

智算集群Training clusters

面向大模型预训练与大规模后训练:整机独享、无损网络、托管调度,可按周、月或年预留。For pre-training and large-scale post-training: dedicated nodes, lossless networking and managed scheduling, reserved by the week, month or year.

  • GPU 裸金属服务器:8 卡整机独享,开放 root 权限Bare-metal GPU servers: whole 8-GPU nodes with root access
  • 专属训练集群:百卡至万卡级,InfiniBand NDR 或 RoCEv2,1:1 无收敛Dedicated training clusters: hundreds to ten thousand GPUs on non-blocking NDR InfiniBand or RoCEv2
  • 整机柜(超节点):GB300 NVL72 等机型Rack-scale systems: GB300 NVL72 and similar
  • 托管 Slurm 与 Kubernetes,预装驱动与框架Managed Slurm and Kubernetes, with drivers and frameworks preinstalled
  • 并行文件系统与 GPUDirect StorageParallel file system with GPUDirect Storage

千卡级集群以周为单位交付,可预约锁定容量。Clusters of a thousand GPUs or more are delivered in weeks; reserve ahead to lock in capacity.

02 — 推理与开发Inference & development

弹性算力Elastic compute

面向推理、微调与开发调试:分钟级开通、随开随停,按秒、按卡时或按词元(Token)计费。For inference, fine-tuning and development: ready in minutes, stop anytime, billed by the second, the GPU-hour or the token.

  • GPU 云服务器:1 / 2 / 4 / 8 卡规格,分钟级开通GPU instances: 1, 2, 4 or 8 GPUs, ready in minutes
  • 推理服务:专属端点或 Serverless GPU,按秒计费、自动扩缩容Inference endpoints: dedicated or serverless GPU, per-second billing, autoscaling
  • 模型 API(MaaS):主流开源与商用模型,按百万词元计费Model API (MaaS): leading open and commercial models, billed per million tokens
  • 容器实例与开发环境:预置镜像,开箱即用Containers and development environments: prebuilt images, ready to use

按量实例可转为包年包月,长期负载的成本更可预期。When a workload settles, move it to a subscription for more predictable cost.

平台能力Platform capabilities

多元异构算力Heterogeneous compute

NVIDIA 与国产 AI 加速卡统一纳管,按负载选型,降低对单一供应商的依赖。NVIDIA and domestic AI accelerators under one control plane. Choose by workload and reduce reliance on any single supplier.

统一管控平台Unified console and API

通过控制台或 OpenAPI 开通与管理资源,内置监控、配额与成本分析。Provision and manage resources from the console or OpenAPI, with monitoring, quotas and cost analytics built in.

高性能存储High-performance storage

并行文件系统与 S3 兼容对象存储,支持 GPUDirect Storage 与检查点高速读写。A parallel file system plus S3-compatible object storage, with GPUDirect Storage and fast checkpointing.

集群可靠性Cluster resilience

断点续训、故障节点自动隔离与自愈,提升有效训练时长(goodput)。Checkpoint-restart plus automatic isolation and recovery of failed nodes, for more goodput from every run.

安全隔离Isolation and security

VPC 与多租户隔离,可选物理隔离的专属资源池。VPC and multi-tenant isolation, with physically isolated dedicated pools on request.

国产算力专区Domestic accelerator zone

昇腾等国产 AI 加速卡资源池,提供框架与算子迁移适配,满足信创要求。Pools of Ascend and other domestic AI accelerators, with framework and operator porting for Xinchuang requirements.

GPU 型号、数量、可用区域(境内 / 境外)与交付周期以实际供应及出口管制政策为准。GPU models, quantities, regions (mainland China or international) and lead times depend on actual supply and export-control policy.

机型与资源Accelerators

主流加速卡,
按需选型。
Leading accelerators,
matched to your workload.

从 PCIe 推理卡到液冷整机柜,按训练、微调或推理选择合适的 GPU 与形态。From PCIe inference cards to liquid-cooled racks, choose the GPU and form factor for training, fine-tuning or inference.

咨询可用资源Check availability

NVIDIA

H200

大模型训练与推理LLM training and inference

显存Memory
141 GB HBM3e
显存带宽Memory bandwidth
4.8 TB/s
卡间互联GPU interconnect
NVLink 900 GB/s
形态Form factor
8 卡 HGX8-GPU HGX

NVIDIA

B200

大规模训练与高吞吐推理Large-scale training and high-throughput inference

显存Memory
180 GB HBM3e
显存带宽Memory bandwidth
8 TB/s
卡间互联GPU interconnect
NVLink 1.8 TB/s
形态Form factor
8 卡 HGX8-GPU HGX

NVIDIA

GB300 NVL72

超大模型训练与推理Training and serving very large models

GPU
72 × Blackwell Ultra
显存Memory
每卡 288 GB HBM3e288 GB HBM3e per GPU
卡间互联GPU interconnect
72 卡 NVLink 域72-GPU NVLink domain
形态Form factor
整机柜液冷Liquid-cooled rack

NVIDIA

L40S

推理、微调与图形渲染Inference, fine-tuning and graphics

显存Memory
48 GB GDDR6
显存带宽Memory bandwidth
864 GB/s
接口Interface
PCIe Gen4 x16
形态Form factor
PCIe 板卡(风冷)PCIe card, air-cooled

AMD

Instinct MI355X

大显存训练与推理Memory-heavy training and inference

显存Memory
288 GB HBM3E
显存带宽Memory bandwidth
8 TB/s
卡间互联GPU interconnect
Infinity Fabric
形态Form factor
8 卡 OAM 平台8-GPU OAM platform

国产 AI 加速卡Domestic AI accelerators

昇腾等Ascend and others

政企与信创场景Public sector and Xinchuang workloads

显存Memory
以具体型号为准Varies by model
软件栈Software
框架与算子迁移适配Framework and operator porting
合规Compliance
信创适配Xinchuang-ready
形态Form factor
服务器或整机柜(超节点)Servers or rack-scale systems

规格为厂商公开参数。机型、数量与可用区域(境内 / 境外)以实际供应为准;部分型号受出口管制政策约束,境内区域仅提供可合规供应的型号。Specifications are vendors' published figures. Models, quantities and regions (mainland China or international) depend on actual supply. Some models are subject to export controls; mainland regions offer only models that can be lawfully supplied there.

技术规格Specifications

每一项,
都用标准口径。
Every spec, defined
by industry standards.

供电、制冷、网络与安全均按行业通用标准描述;设计值与实测值分开披露,可用性按月统计。Power, cooling, network and security are described against industry standards. Design and measured values are reported separately, and availability is measured monthly.

建设标准Design standardTier III按 Uptime Tier III 与 GB 50174 A 级标准设计Designed to Uptime Tier III and GB 50174 Class A
设计 PUEDesign PUE≤1.25年均实测值另行披露Annual measured PUE reported separately
单柜功率Power per rack140 kW液冷最高;风冷 10–50 kWLiquid-cooled max; air-cooled 10–50 kW
计算网络Compute fabric3.2 Tb/s单节点 8 × 400G RDMA8 × 400G RDMA per node
供电架构Power2NUPS 或 HVDC · 柴发 N+1UPS or HVDC · N+1 generators
可用性Availability99.99%供电可用性 SLA,按月统计,不含计划维护Power availability SLA, measured monthly, excluding planned maintenance
供电Power
市电接入Utility feed双路市电Dual utility feeds
UPS / HVDC2N UPS 或 240 V / 336 V HVDC2N UPS or 240 V / 336 V HVDC
后备电源Backup generation柴油发电机组 N+1,后备时长按项目设计N+1 diesel generators; runtime designed per project
储能Energy storage可选储能系统(BESS)Optional battery energy storage (BESS)
制冷Cooling
液冷Liquid cooling冷板式液冷(DLC)为主,浸没式液冷按需Direct-to-chip (cold-plate) first; immersion on request
CDUN+1 冗余N+1 redundant
供液温度Supply temperature温水冷却,参照 ASHRAE W32–W45Warm-water cooling, per ASHRAE W32–W45
风冷Air cooling冷 / 热通道封闭Hot- and cold-aisle containment
网络Network
公网接入Internet accessBGP 多线(电信 / 联通 / 移动),运营商中立Multi-carrier BGP (China Telecom, China Unicom, China Mobile); carrier-neutral
计算网络Compute fabricInfiniBand NDR 或 400GbE RoCEv2,单节点 8 × 400GNDR InfiniBand or 400GbE RoCEv2; 8 × 400G per node
拓扑Topology轨道优化 + 1:1 无收敛胖树Rail-optimized, non-blocking (1:1) fat-tree
互联Interconnection交叉连接 · 云专线 · 数据中心互联(DCI)Cross-connects · Cloud on-ramps · DCI
安全Security
物理安防Physical security7×24 安保、多级门禁、视频监控24/7 guards, layered access control, CCTV
消防Fire protection极早期烟雾探测 + 气体灭火Very early smoke detection with gas suppression
合规Compliance可在等保三级环境交付Can be delivered in MLPS Level 3 environments
运维Operations
监控Monitoring7×24 NOC、DCIM 与动环监控24/7 NOC, DCIM and environmental monitoring
现场支持On-site support远程协助与专家现场支持Remote hands and smart hands
SLA按月统计与报告,不含计划维护Measured and reported monthly, excluding planned maintenance

以上为示例设计指标,具体园区规格以项目合同与现场条件为准。Representative design targets; site-specific figures depend on contract and site conditions.

典型负载Reference workloads

每类负载,
都有参考配置。
A reference configuration
for every workload.

以下为常见 AI 负载的参考配置。最终方案由解决方案架构师根据您的模型、数据与时间表评估确定。Starting points for common AI workloads. A solutions architect sizes the final setup around your models, data and timeline.

大模型预训练LLM pre-training

从零训练或继续预训练基础模型,重点关注线性加速比与长时间稳定运行。Training foundation models from scratch or continuing pre-training, where scaling efficiency and long, stable runs matter most.

规模Scale
千卡级集群Thousand-GPU-class clusters
网络Network
IB NDR,1:1 无收敛NDR InfiniBand, non-blocking
存储Storage
并行文件系统 + 对象存储Parallel file system + object storage
可靠性Resilience
断点续训、故障自愈Checkpoint-restart, self-healing

后训练与微调Post-training and fine-tuning

用领域数据完成 SFT、LoRA 或 DPO,让模型更贴合您的业务。Adapt a model to your domain with SFT, LoRA or DPO on your own data.

规模Scale
8–64 卡8–64 GPUs
方法Methods
SFT / LoRA / DPO
环境Environment
预装驱动与框架Drivers and frameworks preinstalled
交付Lead time
分钟级到天级Minutes to days

推理服务Inference endpoints

在线与离线推理,按时延与吞吐目标做容量规划与压测。Online and batch inference, sized and load-tested against your latency and throughput targets.

形态Deployment
专属端点或 ServerlessDedicated or serverless
压测指标Load-test metrics
TTFT · TPOT · 吞吐TTFT · TPOT · throughput
弹性Scaling
自动扩缩容Autoscaling
计费Billing
按秒或按词元Per second or per token

数据处理与混合云Data processing and hybrid cloud

大规模数据清洗与预处理,与公有云及本地系统统一管控。Large-scale data cleaning and preparation, managed together with your public cloud and on-premises systems.

存储Storage
PB 级Petabyte-scale
互联Connectivity
云专线直连公有云Cloud on-ramps to public clouds
管控Management
统一管控平台Unified console and API
部署Placement
存算就近部署Compute placed next to the data

参考配置仅供选型参考,不构成性能承诺;最终配置以方案评估为准。Reference configurations are a starting point, not a performance commitment; final sizing follows an assessment.

计费模式Pricing models

按您使用算力的方式,
灵活计费。
Pay the way
you use compute.

四种计费模式可组合使用。价格取决于机型、规模、区域与合同期限,请联系我们获取报价。Combine any of the four. Pricing depends on hardware, scale, region and term — contact us for a quote.

弹性Flexible

按量计费On-demand

按卡时计费 · 随开随停Per GPU-hour · Start and stop anytime

  • 适合短期任务与波动负载For short jobs and spiky demand
  • 推理服务可按秒计费Per-second billing for inference endpoints
  • 模型 API 按百万词元计费Model API billed per million tokens
获取报价Get a quote

稳定Steady

包年包月Subscription

按月或按年 · 锁定资源与单价Monthly or annual · Locked resources and rate

  • 适合长期稳定的训练与推理For steady training and inference
  • 资源独享,成本可预期Dedicated resources, predictable cost
  • 到期可续订或调整规格Renew or resize at the end of the term
获取报价Get a quote

设施Facilities

托管与定制Colocation and custom

机柜·月或 kW·月Per rack or per kW, monthly

  • 带宽、交叉连接与运维服务按需叠加Add bandwidth, cross-connects and services as needed
  • 批发型托管与 BTS 按项目报价Wholesale and BTS quoted per project
  • 支持企业定制方案Custom enterprise agreements
获取报价Get a quote

开通流程Getting started

  1. 需求评估Scope

    模型 · 数据 · 时间表Model · Data · Timeline

    解决方案架构师了解您的模型规模、数据量、时间表与合规要求。A solutions architect reviews your model size, data volume, timeline and compliance needs.

  2. 方案与报价Propose

    配置 · 区域 · 计费Configuration · Region · Billing

    给出机型、网络与存储配置,以及区域、交付时间与计费方案。You get a hardware, network and storage configuration, with region, delivery date and billing options.

  3. 部署交付Deploy

    实例分钟级 · 集群以周计Minutes for instances · Weeks for clusters

    实例分钟级开通;千卡级集群以周为单位交付,交付前完成烤机与基准测试。Instances start in minutes. Thousand-GPU clusters are delivered in weeks, burned in and benchmarked before handover.

  4. 验收与运维Accept and operate

    7×2424/7

    按约定指标验收,随后进入 7×24 运维与按月 SLA 报告。Acceptance against agreed metrics, then 24/7 operations with monthly SLA reports.

承诺期限与交付周期为示例,具体以正式报价与合同为准。Commitment terms and lead times are representative; final terms are set in your quote and contract.

常见问题FAQ

您可能关心的问题。Questions, answered.

数据中心在哪些区域?Where are your data centers?

我们通过自建与合作数据中心资源提供服务。具体园区、可用机型与交付周期取决于您的需求与当期资源,请联系解决方案团队获取最新信息。

We serve customers from both our own and partner data center capacity. Specific campuses, available hardware and lead times depend on your requirements and current capacity — contact our solutions team for the latest details.

千卡集群多久可以交付?How long does a thousand-GPU cluster take to deliver?

单卡或单机实例可分钟级开通;千卡级集群通常以周为单位交付,具体取决于机型供应、网络规模与验收要求。建议提前预约,锁定容量与交付窗口。集群交付前均完成烤机与 NCCL 等基准测试。

Single-GPU and single-node instances start in minutes. Thousand-GPU clusters are typically delivered in weeks, depending on hardware supply, fabric size and acceptance requirements. Reserve early to lock in capacity and a delivery window. Every cluster is burned in and benchmarked, including NCCL tests, before handover.

支持哪些计费方式?What billing options do you offer?

GPU 算力服务支持按量计费(按卡时)、包年包月与预留容量(1–3 年承诺);推理服务可按秒计费,模型 API 按百万词元计费。托管按机柜·月或 kW·月计费,带宽与交叉连接另计。

GPU cloud is available on demand (per GPU-hour), by monthly or annual subscription, or as reserved capacity on a 1–3 year commitment. Inference endpoints can bill per second, and the model API per million tokens. Colocation is billed per rack or per kW each month, with bandwidth and cross-connects billed separately.

是否支持国产算力?Do you support domestic AI accelerators?

支持。我们提供昇腾等国产 AI 加速卡资源,并协助完成框架、算子与模型的迁移适配,满足信创要求。国产算力与 NVIDIA 资源可在同一平台统一纳管。

Yes. We offer Ascend and other domestic AI accelerators, and help port frameworks, operators and models to them for Xinchuang requirements. Domestic and NVIDIA resources are managed on the same platform.

液冷改造是否需要停机?Does a liquid-cooling retrofit require downtime?

不一定。改造可分区、分批实施,并配合负载迁移,尽量减少对在运业务的影响;是否需要短时停机取决于现场条件,我们会在现场勘察后给出具体实施方案。

Not necessarily. Retrofits can run zone by zone alongside workload migration to keep disruption to a minimum. Whether any brief downtime is needed depends on the site — we'll set out the approach after a survey.

可以只托管自有服务器吗?Can we colocate just our own servers?

可以。零售型机柜托管以单机柜起步,也提供高密度液冷机位;您可按需叠加 BGP 带宽、交叉连接、云专线,以及远程协助、部署上架等运维服务。

Yes. Retail colocation starts at a single rack, and high-density liquid-cooled positions are available too. Add BGP bandwidth, cross-connects, cloud on-ramps and services such as remote hands or rack-and-stack as you need them.